Re-establish RLC for SRB1 only when receiving RRCReestablishmentRequest
- according to 5.3.7.4 of TS 38.331: 1> re-establish RLC for SRB1;
- gNB:
1) re-establish RLC for SRB1 in nr_rlc_update_id
2) re-establish RLC for remaining RBs concurrently with RRCReconfiguration
issue: gNB) in nr_rlc_update_id the gNB is re-establishing RLC for all
RBs at the same time when receiving RRCReestablishmentRequest
from UE
UE) according to the specs, the UE is re-establishing RLC for
SRB1 with RRCReestablishmentRequest the other RBs are
re-established during RRCReconfiguration (in our case in
nr_rrc_ue_process_RadioBearerConfig) when receiving
reestablishRLC IE in rlc_BearerToAddModList
RLC TX) this leads to RLC counters mismatch after re-establishment:
control PDUs discarded until max nb of retx is reached
and then UL failure occurs
Showing